High Flow Steam Filters

Steam Filter Brochure
Steam Filter Technical Data

Why Choose Micropure Filters

Features and Benefits

Technical Data

Flow rate information for Steam Filter

 
Steam Flow Rate( lb/Hr ) @ 100 psi
Filter Type
Elements/
Housing
1 Micron
10 Micron
25 micron
32 micron
50 Micron
100 Micron
PDF-1442
3
15,750
18,900
22,050
25,200
31,500
63,000
PDF-1448
3
18,000
21,600
25,200
28,800
36,000
72,000
PDF-1454
3
20,250
24,300
28,350
32,400
40,500
81,000
PDF-1460
3
22,500
27,000
31,500
36,000
45,000
90,000
PDF-1466
3
24,750
29,700
34,650
39,600
49,500
99,000
PDF-1472
3
27,000
32,400
37,800
43,200
54,000
108,000
PDF-1478
3
29,250
35,100
40,950
46,800
58,500
117,000
PDF-1484
3
31,500
37,800
44,100
50,400
63,000
126,000
PDF-1490
3
33,750
40,500
47,250
54,000
67,500
135,000
PDF-1496
3
36,000
43,200
50,400
57,600
72,000
144,000
PDF-14102
3
38,250
45,900
53,550
61,200
76,500
153,000
PDF-14108
3
40,500
48,600
56,700
64,800
81,000
162,000
PDF-14110
5
41,250
49,500
57,750
66,000
82,500
165,000
PDF-14120
5
45,000
54,000
63,000
72,000
90,000
180,000
PDF-14130
5
48,750
58,500
68,250
78,000
97,500
195,000
PDF-14140
5
52,500
63,000
73,500
84,000
105,000
210,000
PDF-14150
5
56,250
67,500
78,750
90,000
112,500
225,000
PDF-14160
5
60,000
72,000
84,000
96,000
120,000
240,000
PDF-14170
5
63,750
76,500
89,250
102,000
127,500
255,000
PDF-14180
5
67,500
81,000
94,500
108,000
135,000
270,000
PDF-14182
7
68,250
81,900
95,550
109,200
136,500
273,000
PDF-14196
7
73,500
88,200
102,900
117,600
147,000
294,000
PDF-14210
7
78,750
94,500
110,250
126,000
157,500
315,000
PDF-14224
7
84,000
100,800
117,600
134,400
168,000
336,000
PDF-14238
7
89,250
107,100
124,950
142,800
178,500
357,000
PDF-14252
7
94,500
113,400
132,300
151,200
189,000
378,000

 

Looking for a steam filter with a different pressure or micron level? Contact the sales and engineering department at Micropure Filtration for sizing.

Looking for a steam filter with a High Flow rate? Contact the sales and engineering department about our multi-element High Flow Steam filters.

Check out this case study about our latest Multi-round Steam Filter Project.

Filter Type
Elements
/ Housing
Total Height*
Assembly Width
Conn. to Conn. width
PDF-1442
3
43.5”
18”
32”
PDF-1448
3
43.5”
18”
32”
PDF-1454
3
43.5”
18”
32”
PDF-1460
3
43.5”
18”
32”
PDF-1466
3
43.5”
18”
32”
PDF-1472
3
43.5”
18”
32”
PDF-1478
3
48”
18”
32”
PDF-1484
3
48”
18”
32”
PDF-1490
3
48”
18”
32”
PDF-1496
3
48”
18”
32”
PDF-14102
3
48”
18”
32”
PDF-14108
3
48”
18”
32”
PDF-14110
5
48”
22”
36”
PDF-14120
5
48”
22”
36”
PDF-14130
5
48”
22”
36”
PDF-14140
5
48”
22”
36”
PDF-14150
5
48”
22”
36”
PDF-14160
5
48”
22”
36”
PDF-14170
5
48”
22”
36”
PDF-14180
5
48”
22”
36”
PDF-14182
7
48”
26”
40”
PDF-14196
7
48”
26”
40”
PDF-14210
7
48”
26”
40”
PDF-14224
7
48”
26”
40”
PDF-14238
7
48”
26”
40”
PDF-14252
7
48”
26”
40”

* "Total Height" will vary based on connection size

Example CAD drawing for 3 element 8 inch flange housing

Steam Filter Warranty

Micropure Filtration, Inc. provides a five year limited warranty on all parts except O-rings and media. A one year warranty on filter media is based on periodic Backflushing to prevent overloading. These warranties extend only to components purchased from Micropure or a certified Micropure Filtration Vendor.