Micro-Series

Finite’s Air and Gas Microfiltration Products

Housing Selection

 

Flow (SCFM)/m3/hr
@ 100 PSIG, 1 PSID

Housing Model Number

Port Size

Port Type

# Elmts / Housing*

Element Length

Element Seal Design

.01 um PTFE

.02 um PTFE

MT1N-0110 1” NPT 1 10” D.O.E. 150/254 225/381
MT1N-0120 1" NPT 1 20” D.O.E. 250/424 375/636
MF2N-0310 2" NPT 3 10” 222/FLAT 600/1017 720/1220
MF2F-0310 2" FLANGE 3 10” 222/FLAT 600/1017 720/1220
MF2N-0320 2" NPT 3 20” 222/FLAT 1200/2034 1440/2440
MF2F-0320 2" FLANGE 3 20” 222/FLAT 1200/2034 1440/2440
MF3F-0330 3" FLANGE 3 30” 222/FLAT 1800/3051 2160/3661
MF3F-0520 3" FLANGE 5 20” 222/FLAT 2000/3390 2400/4068
MF3F-0530 3" FLANGE 5 30” 222/FLAT 3000/5085 3600/6102
MF4F-0720 4" FLANGE 7 20” 222/FLAT 2800/4746 3360/5695
MF4F-0730 4" FLANGE 7 30” 222/FLAT 4200/7119 5040/8543
MF6F-1030 6" FLANGE 10 30” 222/FLAT 6000/10,170 7200/12,204
MF6F-1530 6" FLANGE 15 30” 222/FLAT 9000/15,255 10,800/18,306
*Number of elements to order per housing

MT1 Series

  • 316L Stainless Steel
  • Thru-rod housing design
  • 1” NPT threaded inlet and outlet ports
  • Threaded vent and drain connections
  • T-Type (line mounted design)
  • Single double open end element design
  • Cartridge lengths 10” and 20” available
  • Fluorocarbon seals used throughout

MF2 & MF3 Series

  • 316L Stainless Steel
  • Single fluorocarbon o-ring for positive housing seal
  • Swing bolts w/ eyenuts
  • ASME Code - UM Stamped
  • Threaded vent and drain connections
  • Adjustable leg height
  • Flanged or threaded inlet and outlet connections
  • Side inlet, bottom outlet

MF4 & MF6 Series

  • 316 Stainless Steel
  • Single fluorocarbon o-ringfor positive housing seal
  • Swing bolts w/ eyenuts
  • ASME Code - UM Stamped
  • Threaded vent, drain, gauge connections
  • Mechanical cover lift standard
Parker Finite Micro Series
Parker Finite Micro Series
Parker Finite Micro Series
Parker Finite Micro Series

DIMENSION

A

B

C

D

E

WEIGHT

MT1N-0110 13.38 /33.98 4.44 /11.28 1.25 /3.18 N/A N/A 5 /2.28
MT1N-0120 23.38 /59.38 4.44 /11.28 1.25 /3.18 N/A N/A 8 /3.63
MF2N-0310 33.00 /83.82 12.38 /31.45 5.75 /14.60 13.19 /33.50 N/A 82 /37.23
MF2F-0310 33.00 /83.82 13.56 /34.44 8.00 /20.32 12.00 /30.48 N/A 90 /40.86
MF2N-0320 43.06 /109.37 22.44 /56.0 5.75 /14.60 13.19 /33.50 N/A 87 /39.50
MF2F-0320 43.06 /109.37 23.63 /60.02 8.00 /20.32 12.00 /30.48 N/A 95 /43.13
MF3F-0330 53.13 /134.95 33.94 /86.28 8.00 /20.32 11.75 /29.85 N/A 110 /49.94
MF3F-0520 43.06 /109.37 23.88 /60.56 8.00 /20.32 11.75 /29.85 N/A 105 /47.67
MF3F-0530 53.13 /134.95 33.94 /86.21 8.00 /20.3 2 11.75 /29.85 N/A 110 /49.94
MF4F-0720 56.13 /142.57 18.00 /45.72 9.00 /22.86 18.00 /45.72 26.50 /67.31 250 /113.50
MF4F-0730 66.19 /168.12 18.00 /45.72 9.00 /22.86 18.00 /45.72 26.50 /67.31 270 /122.58
MF6F-1030 68.19 /173.20 20.00 /50.80 10.00 /25.40 19.00 /48.26 29.50 /74.93 310 /140.74
MF6F-1530 70.38 /178.70 23.25 /59.06 11.63 /29.54 21.00 /53.34 31.50 /80.01 415 /188.41
Note: Dimensions are in inches/centimeters; weight is in pounds/kilograms.

How To Order Membrane Housings

M

F

6

F

-

15

30

Micro-Series
Line or Floor Mount
Connection
Connection Type
# Elements/ Housing
Element Length
M-Microfiltration T - Line Mount
F - Floor Mount
1 - 1” Conn.
2 - 2” Conn.
3 - 3” Conn.
4 - 4” Conn.
6 - 6” Conn.
N - NPT (1-2” only)
F - Flange (3-6” only)
01 - 1 Element
03 - 3 Elements
05 - 5 Elements
07 - 7 Elements
10 - 10 Elements
15 - 15 Elements
10 - 10”
20 - 20”
30 - 30”
(Elements must be ordered separately)