Culinary Steam Filters

Culinary Steam Filter Brochure
Culinary Steam Filter Technical Data

Why Choose Micropure Filters

Features and Benefits

Technical Data

Flow rate information for Culinary Steam Filters

Steam Flow Rate @ 100 psi & 3 Micron Absolute
Filter Type (lb/hr) Pipe Size
Available** (Inch)
Pipe Connection Available*

Filter
We
ight (lbs)

PDF-0602 75 0.5,1 FNPT, Tri-Clamp, Flange 8
PDF-0604 150 0.5,1 FNPT, Tri-Clamp, Flange 9
PDF-0606 225 0.5,1 FNPT, Tri-Clamp, Flange 10
PDF-0802 300 1,1.5,2 FNPT, Tri-Clamp, Flange 14
PDF-0804 600 1,1.5,2 FNPT, Tri-Clamp, Flange 15
PDF-0806 825 1,1.5,2 FNPT, Tri-Clamp, Flange 15
PDF-0808 975 1,1.5,2 FNPT, Tri-Clamp, Flange 16
PDF-0810 1,200 1,1.5,2 FNPT, Tri-Clamp, Flange 16
PDF-0812 1,375 1,1.5,2 FNPT, Tri-Clamp, Flange 18
PDF-1008 1,500 2,2.5,3 FNPT, Tri-Clamp, Flange 30
PDF-1010 1,725 2,2.5,3 FNPT, Tri-Clamp, Flange 30
PDF-1012 2,250 2,2.5,3 FNPT, Tri-Clamp, Flange 31
PDF-1014 2,475 2,2.5,3 FNPT, Tri-Clamp, Flange 32
PDF-1408 3,000 2,3,4 FNPT, Tri-Clamp, Flange 44
PDF-1410 3,750 2,3,4 FNPT, Tri-Clamp, Flange 45
PDF-1412 4,500 2,3,4 FNPT, Tri-Clamp, Flange 48
PDF-1414 5,250 2,3,4 FNPT, Tri-Clamp, Flange 50
PDF-1416 6,000 2,3,4 FNPT, Tri-Clamp, Flange 54
PDF-1418 6,750 2,3,4 FNPT, Tri-Clamp, Flange 56
PDF-1420 7,500 2,3,4 FNPT, Tri-Clamp, Flange 58
PDF-1426 9,750 2,3,4 FNPT, Tri-Clamp, Flange 62
PDF-1432 12,000 2,3,4 FNPT, Tri-Clamp, Flange 65

*Other Pipe Connections available upon Request*

**Standard pipe sizes for filters. In-between or larger connections available

Looking for a steam filter with a different pressure or micron level? Contact the sales and engineering department at Micropure Filtration for sizing.

Looking for a steam filter with a High Flow rate? Contact the sales and engineering department about our multi-element High Flow Steam filters.

Check out this case study about our latest Multi-round Steam Filter Project.

Dimensional Chart

Filter Type
A
(in)
B
(in)
C
(in)
D
(in)
Filter Weight
(lbs)
PDF-0602
6.5
9.5
12
3.15
8
PDF-0604
6.5
9.5
12
3.15
9
PDF-0606
6.5
9.5
12
3.15
10
PDF-0608
6.5
9.5
12
3.15
12
PDF-0802
8.5
11.5
15.5
4
14
PDF-0804
8.5
11.5
15.5
4
15
PDF-0806
8.5
11.5
15.5
4
15
PDF-0808
8.5
11.5
15.5
4
16
PDF-0810
8.5
11.5
15.5
4
16
PDF-0812
8.5
11.5
15.5
4
18
PDF-1008
13
15.5
20.5
5
30
PDF-1010
13
15.5
20.5
5
30
PDF-1012
13
15.5
20.5
5
31
PDF-1014
13
15.5
20.5
5
32
PDF-1408
13
26
33.5
6
44
PDF-1410
13
26
33.5
6
45
PDF-1412
13
26
33.5
6
48
PDF-1414
13
26
33.5
6
50
PDF-1416
13
26
33.5
6
54
PDF-1418
13
26
33.5
6
56
PDF-1420
13
26
33.5
6
58
PDF-1426
13
26
33.5
6
62
PDF-1432
13
26
33.5
6
65

 

Steam Filter Technical Data

Maximum Operating Pressure 232 psig 16 bar
Maximum Differential Pressure 75   psid 5.2 bar
Maximum Reverse Pressure 75   psid 5.2 bar
Pore Sizes 1,2,3,5
(Other sizes available upon request)
Material of Construction:
Housing 304 SS
Segmented Filter Discs 304 SS
Filter Media 304 SS
O-Rings EPDM

Steam Filter Warranty

Micropure Filtration, Inc. provides a five year limited warranty on all parts except O-rings and media. A one year warranty on filter media is based on periodic backflushing to prevent overloading. These warranties extend only to components purchased from Micropure or a certified Micropure Filtration Vendor.

Culinary Steam Standards

3A Accepted Practices for a Method of Producing Steam of Culinary Quality requires 95 % particulate filtration to 2 microns and larger (Reference No. 609-00;D.2).