Technical Data

Maximum Operating Pressure 232 psig 16 bar
Maximum Differential Pressure 75   psid 5.2 bar
Maximum Reverse Pressure 75   psid 5.2 bar
Maximun operating temp      250°F/121°C  
Maximun Intermittent temp 400°F/204°C  
Pore Sizes .2 micron absolute.
(Other sizes available upon request)
Material of Construction:
Housing 304 SS
Segmented Filter Discs 304 SS
Filter Media 304 SS
Rainproof Cover 304 SS

Recommended Sterilization Procedures

Saturated Steam   20 mins @ 250°F
Hot Air 12 hrs   @ 250°F

Pressure Differential Tables

BA-8202 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 22 3.00 5.01 0.0062
  30 4.00 6.68 0.0083
  37 5.00 8.35 0.0104
  60 8.00 13.35 0.0166
  75 10.00 16.69 0.0207
  112 15.00 25.04 0.0311
BA-1402 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 75 10.00 16.69 0.0207
  90 12.00 20.03 0.0249
  112 15.00 25.04 0.0311
  150 20.00 33.38 0.0414
  187 25.00 41.73 0.0518
  225 30.00 50.07 0.0621
BA-1406 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 225 30.00 50.07 0.0621
  262 35.00 58.42 0.0725
  299 40.00 66.76 0.0829
  374 50.00 83.45 0.1036
  449 60.00 100.14 0.1243
  524 70.00 116.83 0.1450
BA-1410 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 374 50.00 83.45 0.1036
  412 55.00 91.80 0.1139
  449 60.00 100.14 0.1243
  524 70.00 116.83 0.1450
  599 80.00 133.52 0.1657
  674 90.00 150.21 0.1864
BA-1414 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 524 70.00 116.83 0.1450
  561 75.00 125.18 0.1554
  599 80.00 133.52 0.1657
  674 90.00 150.21 0.1864
  749 100.00 166.90 0.2071
  823 110.00 183.59 0.2279
BA-1002 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 37 5.00 8.35 0.0104
  60 8.00 13.35 0.0166
  75 10.00 16.69 0.0207
  112 15.00 25.04 0.0311
  112 15.00 25.04 0.0311
  150 20.00 33.38 0.0414
BA-1404 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 150 20.00 33.38 0.0414
  187 25.00 41.73 0.0518
  225 30.00 50.07 0.0621
  299 40.00 66.76 0.0829
  374 50.00 83.45 0.1036
  449 60.00 100.14 0.1243
BA-1408 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 299 40.00 66.76 0.0829
  337 45.00 75.11 0.0932
  374 50.00 83.45 0.1036
  449 60.00 100.14 0.1243
  524 70.00 116.83 0.1450
  898 120.00 200.28 0.2486
BA-1412 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 449 60.00 100.14 0.1243
  487 65.00 108.49 0.1346
  524 70.00 116.83 0.1450
  599 80.00 133.52 0.1657
  674 90.00 150.21 0.1864
  749 100.00 166.90 0.2071
BA-1416 GPM
(Rounded)
SCFM M3/hr PSID
Design Flow 599 80.00 133.52 0.1657
  636 85.00 141.87 0.1761
  674 90.00 150.21 0.1864
  749 100.00 166.90 0.2071
  823 110.00 183.59 0.2279
  898 120.00 200.28 0.2486
GPM: Gallons per minute
SCFM: Standard cubic feet per minute
M3/hr: Cubic meters per hour
PSID: pounds per square inch (pressure) drop
 
NOTE: please check the pressure capacity of your tank to ensure the proper tank vent selection.

Warranty

Micropure Filtration, Inc. provides a five year limited warranty on all parts except O-rings and media. A one year warranty on filter media is based a maximum loading of 140 million particles per cubic meter (normal conditions).   These warranties extend only to media purchased from Micropure or a certified Micropure Filtration Vendor.